Why is the heated towel rail leaking and how to fix the problem?

Content
  1. Leakage reasons
  2. Preparation of tools and materials
  3. How do I fix the problem?
  4. Prophylaxis

Owners of comfortable homes often face the problem of pipe leaks, and heated towel rails are no exception. If even a slight leak is detected, it is necessary to determine the cause of the leak as soon as possible and take urgent measures to eliminate it.

Leakage reasons

Not only old heated towel rails can leak, but also fairly modern devices installed quite recently, and there can be a great many reasons for this. Below are considered the most common of them, which entailed a violation of the integrity of communications.

Loosening of flare nuts

Loose nuts are one of the most common causes of leaks. Weakening occurs due to shrinkage processes inside the pipe, resulting from temperature changes in the heat carrier.

With a sharp drop in water temperature, the pipes cool down and begin to narrow. As a result, the tightness of the threaded connection is broken, and the heated towel rail begins to leak at the junction with the pipe.

Nuts can also come loose from installation errors when tightening has been performed incorrectly. Under-tightened, as well as over-tightened nuts are often the cause of malfunctions in heated towel rails.

Corrosive processes

Rust is often one of the causes of leaks. Corrosion occurs as a result of the influence of stray currents within the network, as well as due to the presence of oxygen in the water. In this regard, even new heated towel rails are not immune to rust and leaks.

Worn gaskets

This reason is the most common.

Worn out rubber or silicone gaskets cause leaks at the junction of heated towel rails with common building communications for heating or hot water supply.

A crookedly installed gasket may also be the cause of the leak. The most resistant to high temperatures are fluoroplastic gaskets, which are very reliable and have a long service life.

Defective appliance

Installing a defective heated towel rail in the bathroom leads to a leak immediately after installation. No one is insured against the purchase of such products, therefore, the payment receipt and the passport of the device must be kept until the end of its warranty period established by the manufacturer.

Installation errors

Very often, a perfectly serviceable coil begins to leak due to improper installation. Therefore, to prevent such situations, the installation of heated towel rails should be trusted only by professionals.

Mechanical damage

Sometimes the joints start to leak as a result of their damage by some foreign object, for example, when doing repair work in the bathroom.

Incorrect piping

When installing communications, hot water pipes may be led out crookedly and do not correspond to the dimensions of the heated towel rail.

Due to uneven joining of pipes, threaded connections begin to leak.

This also includes the appearance of a leak in the event of errors in the formation of rotary nodes.

Powerful water hammer

Often, strong hydraulic shocks occur inside the water supply system, as a result of which the threaded connections do not withstand and leak.

Preparation of tools and materials

After the reason for the leakage of the heated towel rail is established, and it is decided to eliminate it yourself, it is necessary to prepare some tools and materials. When doing home repairs, you cannot do without a wrench, new gaskets, a construction knife, polymer composition, FUM tape, tow and an anti-corrosion agent. Some leaks may require cold welding and silicone sealant.

How do I fix the problem?

The way to eliminate a heated towel rail leak entirely depends on the cause of the leak, and in each case, the approach to solving the problem will be different. Regardless of the nature of the damage, the first and general action for any repair will be to shut off the access of water to the heated towel rail.

If the leak is caused by wear of the gasket, then a layer of paint is removed from the union nuts and unscrewed with an adjustable wrench. Then the threaded connection is disassembled, the worn out gasket is removed, a new one is installed and the union nuts are tightened. Then the water supply to the heated towel rail is resumed and the quality of the repair is checked. In the absence of factory gaskets, you can take a piece of rubber, put an old gasket on it, circle it with a ballpoint pen and cut it out. If the gasket was recently replaced and water is still leaking, the cause may be a loose union nut. In order to fix the problem, it is enough to tighten the nut with an adjustable wrench.

If there is no union nut in the threaded connection, and the coil is connected to the pipes using couplings, then the repair is performed somewhat differently than in the previous case.... With this method of connection, it is important that the cavities between the threads are filled as much as possible with FUM tape or tow. Otherwise, water seeps into the free space between the pipes and the coupling and starts dripping.

It is quite simple to carry out such repairs with your own hands, but there are still some nuances. For example, in the absence of experience in using FUM tape, it is better to use tow. The fact is that it is rather difficult to determine the optimal amount of tape per eye.

If you wind it a little less than necessary, then the water will ooze along the thread. If you wind a little more, then when the coupling is tightened, the excess tape will be cut off and it will not be possible to achieve tightness.

Therefore, in the absence of experience in plumbing work, it is better to use tow.

  • A strand is separated from the total coil, the thickness of which is equal to the depth of the thread, and its length would provide winding on the thread in one and a half to two layers.
  • The tow is twisted, retreating from one end 5-6 cm, and they begin to wind on the thread in the direction of the turns (clockwise).
  • Having reached the end, unfold and wind the second layer in the opposite direction.
  • Then the remaining 5-6 cm is wound from the center of the thread to its end located at the end of the pipe.
  • Sealant or Unipak paste is applied on top of the tow and wait for the linen material to be completely impregnated.
  • At the last stage, the clutch is wound by hand on the reel and tightened with an adjustable wrench.

Another reason for leakage of threaded connections can be through a rusted section of the thread under the coupling. In such cases, it will not be possible to cope with the means at hand and you cannot do without dismantling the damaged area. Necessary call a locksmith as soon as possible and change the rusted area or the entire pipe.

Sometimes, under the influence of stray currents, pinholes appear on ungrounded coils - fistulas. If their size is not too large, and the water does not drip much, then you can try to cope on your own.

To do this, in a plumbing store, they purchase a special wire designed for soldering small fistulas. Then they turn off and drain the water from the heated towel rail, clean the damaged area with fine sandpaper and degrease with acetone.After that, a gas hand torch is ignited, the damaged area is heated and the solder is leaned against it. The wire begins to melt and fills the hole with liquid metal. Excess drops are quickly removed from the pipe surface, without waiting for them to set.

If the heated towel rail is dripping at the place of welding, then it is unlikely that it will be possible to eliminate the leakage on your own, you will need the help of a specialist... Before the arrival of the locksmith, you can put a clamp or use cold welding, but such measures are temporary and cannot be applied permanently. A failed device is replaced with a new one.

If the heated towel rail began to leak due to an incorrect calculation of the installation angle or due to a violation of the geometry of the liner, then in this situation only the leveling of the pipe level will help, and for a short time - installation of a thicker gasket.

If the water coil in the bathroom is constantly leaking, then the cause is most likely in stray currents, which cause the rapid appearance of rust. In this case, it is necessary to purchase a new device, ground it as soon as possible and treat it from the inside with a polymer composition. The problem of stray currents is typical for old houses, therefore, experts recommend installing Lesenka heated towel rails in them. Such models have special protection against the formation of electrochemical corrosion and are not susceptible to rust.

Prophylaxis

A current heated towel rail is a very dangerous phenomenon, and if nothing is done, then very serious problems can follow.

A breakthrough of boiling water can seriously injure the residents, as well as flood the neighbors below.

Taking timely preventive measures is the best way to avoid such situations.

  • If the quality of the tap water is very poor, then it is recommended to install inlet filters.... Water with a large amount of impurities has a negative effect on pipes and contributes to the appearance of leaks.
  • Particular attention should be paid to the operation of the ventilation system in the bathroom, and if faults are found in it, they should be immediately eliminated. In a humid, poorly ventilated area, pipes corrode quickly, regardless of the material from which they are made.
  • The best option for preventing leaks is to install a device in which there is no water - an electric heated towel rail. Unlike the water analogue, the electric coil is independent of the pressure in the network and the presence of a heat carrier in the pipes. It can be used all year round, regardless of the summer shutdowns of hot water supply. In addition, most modern samples are equipped with thermostats, which allows you to set the desired temperature yourself. When leaving the house, the electric coil can be turned off so that it does not wind up energy, and in the autumn-spring period, when the central heating has not yet been turned on or has already been turned off, it can be used to heat the bathroom.

You need to purchase a heated towel rail only in specialized stores, remembering to check the accompanying documentation and certificates of conformity... Recently, cases of sale of counterfeit products of well-known plumbing brands, the quality of which leaves much to be desired, have become more frequent. When buying, you should carefully inspect the device for defects and do not hesitate to ask the seller to release it from the packaging. If this is not done, then the probability of buying a defective product is quite high, and its return will cost time and nerves. In this regard, it is better to purchase plumbing fixtures from trusted suppliers who have been on the market for a long time and value their reputation.

For information on what to do if a heated towel rail leaks, see below.