How to bleed air from a heated towel rail?
The heated towel rail in its shape can be made as M-shaped, U-shaped or in the form of a "ladder". Many people think that this is the simplest heating pipe, but this is completely wrong. It so happens that he is suffocated, because of which he simply stops heating up. And then you need to somehow remove the air from the inside, or break through the airlock so that it starts working correctly again.
A malfunctioning device can cause mold to appear in the bathroom. It will be useful for everyone to find out how it is possible to bleed air correctly from a heated towel rail. In addition, you should figure out why air locks are formed, in general, and when there is no way to remove air.
Causes of air congestion
This phenomenon can form at the top of the heated towel rail in several situations.
-
Incorrect connection of the dryer. To achieve the greatest efficiency and productivity, as well as to avoid problems for yourself and your neighbors, when installing a heated towel rail, you must comply with a number of certain standards. In particular, the narrowing of the pipes should not be allowed, slopes must be fully observed, as well as the connection diagram.
-
Turning off hot water in summer with its subsequent restart. The air that gets inside during this process can accumulate just in the heated towel rail.
-
Incorrect shape of a particular fixture. This is usually found in products from Chinese manufacturers who do not go into too much engineering detail. As a result, models with pipes of small thickness and sharp drops enter the market, where a similar plug usually forms at the first opportunity.
-
There are cases when hot water in pipes evaporates extremely slowly. The reason for this is the formation of bubbles inside, which prevents the liquid from moving normally.
Signs of a problem
If we talk about the signs of a problem of the nature under consideration, then it should be said that when using such a device, it first starts to heat up worse and worse, and after a while it simply becomes cold. The air that has accumulated inside does not allow the liquid to circulate normally in the coolant, which becomes the cause of the problem. And there is only one way to fix the problem - to bleed the air. And here it should be borne in mind that the heated towel rail is not included in the heating circuit, but in the hot water supply system.
The reason for this is that the heating is turned off in the summer, and the heated towel rail must be hot at any time of the year. After all, its main task will be to maintain a dry atmosphere in the bathroom.
If a heated towel rail stops working, it is only a matter of time before mold and mildew forms on the walls. In especially difficult cases, this can cause damage to the decoration of the room, not to mention the fact that people may develop any kind of illness. And there is no need to even talk about reducing the usability of the bathroom. If the heated towel rail is made of steel, then in the absence of a coolant in it for a long time, the steel will simply oxidize in air, which will cause corrosion. And this may be the reason for the depressurization of the pipe and the flooding of the room.
How to expel air?
Now let's figure out what needs to be done to get rid of the air in the heated towel rail. Consider two options for the design of this device: with and without a Mayevsky crane. Besides, it should be understood that in order to eliminate this problem in the operation of the device in question, it is necessary to take into account a number of features and points.
But in general, each person can do this work without the need to involve a specialist, which will save not only time, but also money.
With a Mayevsky crane
Few know what to do if you want to bleed air from a heated towel rail. The best option would be to install a special valve that will act as a bleed valve. It is called the Mayevsky crane. Modern models of heated towel rails are already equipped with such a tap. This is not a water tap - it is not used to shut off water, but acts just as an air vent.
Before starting the process, let's figure out how the device works. This element consists of two parts:
-
adjustment screw;
-
needle-type valve.
To get rid of the airlock using a Mayevsky crane, you need to take a special key that turns the screw, or a flat-type screwdriver and open the valve.
When the air is completely out, the screw must be tightened.
An indicator of this will be that water will begin to pour from the tap. Note that if everything is done correctly, then after a short period of time the heated towel rail will start heating, after which it will become hot and will work as usual.
Without tap
This method can be called classic or standard. The solution in this case will be obtained using the usual drainage of water from the heated towel rail. But everything is not so simple here, because it will matter where a person lives. If we are talking about a high-rise building, then you need to study the diagram in order to understand where it is possible to open the crane. If the descent is located in your apartment, then you can do it yourself without any problems. To do this, you will need to perform certain actions.
-
First, you need to unscrew the nut that will connect the hot water pipe to the dryer. To unscrew this element, you will need to use an adjustable wrench.
-
You should first have a container where you will drain the water, if the need arises.
-
After that, you need to wait for the moment when, after weakening the product, you can hear hissing sounds of various kinds.
-
All that remains is to drain the water.
When the air stops coming out, that is, there will be no more inside it, the nut can be screwed back.
But it happens that the above technique does not make it possible to eliminate the malfunction of a heated towel rail with both side and bottom connections. Then you can use other options.
It happens that in buildings erected a long time ago, it is required to approach the situation individually, taking into account the specifics of a particular building. You can try to contact the person who lives on the top floor and ask him to bleed air from his home. This can be explained by the fact that the route of the riser, along which hot water flows, passes precisely from the lower floor to the upper, where it makes a loop and goes back down. Considering that air is lighter than water, which is logical, it will accumulate precisely at the highest point of the system. Here you will need to do the same steps that were mentioned above. You just need to do them right here, and not in your apartment.
If the house is 9-storey or high-rise, then usually the pipe and the hot water outlet according to the standard project are placed in the attic.
Therefore, in order to get to it, you should adhere to a similar algorithm: you need to open the tap and drain the water into the sewer.But this area is often off-limits to outsiders, and only plumbing officials have access to it. In this case, it would be better, indeed, to call plumbers who will be able to perform the required actions, having previously opened the attic.
If the building where the person lives does not fit any generally accepted characteristics of buildings, it remains only to call representatives of the special plumbing servicethat will surely help a person understand the problem and troubleshoot the heated towel rail.
In what cases is air removal not possible?
However, there are cases when it is simply not possible to remove air from the above-mentioned device. For example, it is guaranteed that you will not be able to do this if the strapping of the heated towel rail is incorrect. For example, if it is very close to the riser. This is also impossible if the so-called dead loop is made above the level of the connection to the riser. This section will permanently air the entire system, and it is not possible to release an air-type plug from it, especially if the pipe is routed using a hidden technique.
When the coolant is supplied from below in the riser, the narrowing of the bypass causes the loss of circulation. For this reason, in the water, which begins to stagnate, there is an intense release of air. That is, it turns out that one inconvenience is superimposed on another.
If a person does not know in which direction the water is supplied, then it would be better to connect a heated towel rail using a bypass with a standard diameter.
That is, as you can see, bleeding the airlock from the heated towel rail is easiest to carry out using the so-called Mayevsky crane. In rare cases, when the device does not have an air vent, it will be enough just to slightly loosen the union nut, which is located on its outlet pipe, taking into account the circulation system, and release air from the system. This will be the simplest and most convenient solution to the problem of an airlock and unstable operation of a heated towel rail.
You can find out what to do if the heated towel rail does not fully warm up from the video below.
The comment was sent successfully.